Model E-4-1111H-GE

特 點:
 |
NIST
可追溯測定方法,多種露點感應器可搭配使用 |
 |
RS-232-C 數位訊號輸出,可任意劃分測試範圍 |
 |
獨創"PACER"自動光學平衡功能可消除鏡面污染所 造成
的數據偏差 |
 |
最新科計產品, 儀器不需經常校正 |
 |
在控制面板上能清楚顯示鏡面狀況 |
 |
鉑金溫度測試系統可準確量測露點溫度
|
應用對象:
 |
工業製程之露點濕度連續監測 |
 |
高科技精密工業半導體製造工廠環境 |
 |
實驗室濕度儀器標準校正 |
 |
潔淨室及乾燥室之濕度測試 |
 |
動力及精密儀器用氣體濕度測試 |
 |
引擎排氣,
熱處理及燃燒氣氛監測 |
 |
環境試驗箱及乾燥機具之濕度測試
|
原廠目錄下載 (PDF Format, 2 pages, 160
KB.)
Chilled
Mirror Hygrometer-Transmitter, E4-1111H-GE
|
|
Description
Precision Duct Mounted Humidity Transmitter with
Integrated Chilled Mirror Sensor
The model
E4-1111H-GE dew point transmitter was derived from time proven chilled
mirror technology, which is widely used for precision humidity
measurement in metrology and standards labs worldwide.
This configuration was developed to measure and
control water vapor injection into the intake of gas and liquid fueled
power turbines, however the design is applicable to many applications
where accurate and repeatable humidity measurement is required. This
technology was chosen because power turbines require the precise
metering water vapor injection is the combustion chamber to reduce
pollutant emissions. Water vapor is also added to the intake of the
turbine to increase the mass flow which in turn increases compression
and electrical power output. The Model E4-1111H-GE is a laboratory grade
chilled mirror hygrometer, designed to meet the requirements of
industrial applications.
The transmitter is suitable for operation in a wide
range of environmental conditions, including outdoor air. The sensor
fully recovers from condensation and exhibits negligible long-term
drift. The electronic components used are of the highest industrial
quality. Each unit is calibrated to NIST traceable reference standards
and the E4-1111H-GE is suitable for use as a dew point transfer
standard. General Eastern’s manufacturing and quality system certified
to ISO- 9001 standards. For more information on the theory and operation
of General Eastern’s Chilled Mirror Hygrometers, contact us to obtain
a catalog and application assistance.
Features and Benefits
 |
Utilizes the time
proven single stage 1111H chilled mirror sensor. |
 |
Sensor fully recovers
from condensation. |
 |
Direct primary dew
point measurement. NIST traceable. |
 |
Provides linear 4-20mA
Signal. |
 |
RS-232 Interface. |
 |
Equipped with patented
PACER self-cleaning & optical balancing system. |
 |
Sensor wetted
components are inert. Optional platinum mirror for more aggressive
environments. |
 |
High accuracy: ± 0.2°
C dew/frost point. |
 |
No long-term drift.
|
 |
Equipped with membrane
filter. |
 |
Mirror is easily
accessible for manual cleaning. |
 |
Optional temperature or
pressure sensor input for %RH, absolute humidity or mixing ratio. |
|