Dew-Stat MA-99
壓縮空氣用露點溫度測定器易於操作的露點溫度量測儀器, 適用於醫院呼吸用壓縮空氣之水份含量測試
Features:
 |
Breakthrough
self-cleaning technology |
 |
No recalibration ever
required |
 |
Precision NIST-traceable fundamental dew point
measurement |
 |
Meets NFPA-99
requirements |
 |
Continuous
controlling chilled mirror technology |
 |
Self-contained
integrated package.
|
原廠目錄下載
(PDF Format, 2 pages, 51 KB.)
Chilled
Mirror Hygrometer, Model Dew-Stat MA-99
|
|
SPECIFICATIONS
Performance:
Accuracy:
±1.0ºF dew point from 30º to 50ºF,±2.0º dew point over full
measurement range Repeatability: ±0.2ºC Measurement Range:
+20º to +95ºF dew point (at 95ºF ambient temp.,55 psig), +10º
to +77ºF dew point (at 77ºF ambient temp., 55 psig) Sample Flow: 1 scfh (settable, 0.5 -
2.0 scfh with integral throttling valve and flow meter) Autoclean Function: Programmable
interval, requires 20 psig minimum AFAC
(Anti-False Alarm Circuit): ON or OFF, DIP switch
selectable under access panel.
Physical
Dimensions:
12"H x 10"W x 8"D Case Material: Molded thermoplastic Weight:
10 lbs. Connections: Air: 1/8" NPTF, top of enclosure Electrical:
Terminal strip, 12 gauge wire maximum, bottom of
enclosure Sample Air Vent: Open, unobstructable, bottom
exit Environmental: Constructed to NEMA-12 requirements Sensor Mirror:
Replaceable Mounting:
Vertical, Wall mount Electrical Env.: Fast transient burst
per IEC 801-4; ESD per IEC 801-2; Line sure per IEC 801-5 Filter:
In-line, replaceable
Functional
Outputs: Alarm:
1
Form C, 2 amps, 240 VAC/24 VDC resistive load, non-latching, NO/NC/COM
field-settable via switch under access panel, automatic
reset. Trip Conditions:
measured dew point above alarm set point; sensor head left open (time
delay) Audible Alarm: 85 dBA at 3 feet, variable tone, silence button on
front panel, automatic reset Indicators: 3 1/2 digit LED dew point
readout with º/º switchable display. LED indicators for the following
conditions: Auto-clean, Out of Range, Service; Alarm Adjustable visual
flow meter with graduations 0-2 scfh Diagnostics: Water phase change calibration check Analog (opt.):
4-20mA DC, 500 ohm maximum load
Inputs: Power: 115 VAC (+10% / -15%), 60 Hz, 35
watts max. Operating Ranges: Ambient Temperature: +32º to +120ºF Sample Pressure:
0-150
psig
Factory Setting (field resetable): Temperature
Units: ºF Alarm Point: 39ºF Autoclean: Every 3 hours AFAC: Enabled Sensor Open Alarm:
20 minute delay before
alarm.
|